Put it near the DUT.
A compact isolated instrument can sit beside a device, fixture or sensor setup, reducing long force and sense cable runs.
Meet the PRX-SMU-001. A compact, isolated source-measure instrument built for standalone operation and the PROBAREX modular platform.
Explore the SMU ↗Discover the platformPROBAREX began with a practical need for capable source-measure instrumentation at a more accessible cost per channel.
The PROBAREX platform connects instrument cards through shared chassis and backplane infrastructure. Each card retains its own instrument function; the SMU also operates in a standalone enclosure. A future PROBAREX chassis adds shared infrastructure as your system grows.
A compact isolated instrument can sit beside a device, fixture or sensor setup, reducing long force and sense cable runs.
The platform is intended to carry one instrument into a coordinated multi-card system with common timing and control.
Replaceable instrument cards make repair and expansion part of the architecture from the beginning.
Apply a voltage and measure current, or control current and measure voltage. Explore device behavior with two-wire or remote Kelvin sensing and a dedicated guarded low-current path.
Conceptual operating quadrants. Available output depends on voltage, current, compliance and thermal limits.
| Output voltage | ±40 V full range / ±4 V low range |
|---|---|
| Source / sink current | Up to approximately ±200 mA |
| Power envelope | Up to approximately 8 W at DUT terminals |
| Current measurement | Nominal ±200 mA, ±20 mA and guarded ±20 µA ranges |
| Sensing | Two-wire local / four-wire remote Kelvin |
| Compliance | Independent positive and negative current limits |
| Control | Analog CV/CC loops with digital supervision |
| Interfaces | Standalone USB and RS-485; PROBAREX card-edge interface |
| Protection | Hardware fault latch, output inhibit and relay disconnect |
A 20-bit voltage-command DAC provides ideal steps of approximately 76.3 µV on the ±40 V range and 7.63 µV on the ±4 V range. ADS1263 conversion and external precision references support measurement and calibration. Actual accuracy and useful resolution depend on the complete analog system.
Tens-of-nanoamps measurement is a design objective. Useful measurement into the hundreds-of-picoamps region remains a characterization goal, subject to leakage, guarding, cleanliness, noise and settling.
Device I–V characterization, diode and transistor evaluation, sensor excitation and readout, leakage-current investigations, and automated source-measure sequences. Application performance will be established during validation.
A compact 116 × 176 × 71 mm enclosure with an integrated touchscreen for local control and USB and RS-485 for remote operation.
A top-mounted 3.5-inch capacitive touchscreen brings settings, measurements and plots to the instrument. The front OLED keeps essential readings visible from the bench.
The PRX-SMU-001 supports local touchscreen control, remote operation and stacking. Stacking covers the top touchscreen; the front OLED keeps essential readings visible.
The rear panel brings USB, RS-485 and 24 V DC power together, alongside the power button and guarded input connector.
A clear view of the connections behind the standalone instrument.
The single-channel enclosure measures 116 mm wide, 176 mm deep and 71 mm high—approximately 4.57 × 6.93 × 2.80 inches. The three views below share a common scale.
The main PCB has a nominal footprint of approximately 100 × 160 mm (3.94 × 6.30 inches). The card combines source-measure circuitry, isolated power conversion, analog control loops, conversion, protection and its own controller.
The reference rendering shows the main PCB and its front-terminal mezzanine before separation. In the assembled chassis, the mezzanine moves to the front panel.
The SMU is the first card for PROBAREX, the modular backplane platform that connects instruments into one system. The planned chassis shares power, cooling, communications and synchronization while each instrument retains its own function.
The current platform direction explores up to sixteen cards in opposing front and rear slot banks. Mechanical design, thermal capacity and final channel count remain development items.
The backplane provides private low-speed serial links, a common 10 MHz reference, differential system synchronization, a 7.3728 MHz ADC clock, card event signaling and a chassis output-inhibit path. Reserved high-speed lanes provide options for future cards. Their protocols and bandwidth are still to be defined.
After the SMU, the proposed development sequence expands into power delivery, controlled loading and waveform capture.
Precision source and measurement for device characterization and automated testing.
A two-channel programmable supply built around independently floating outputs, not a conventional common-ground bench design. Channels can be connected in series, configured as positive and negative rails, or run independently without creating unwanted ground paths.
Programmable steady and changing loads for power supplies, batteries and converters.
Waveform acquisition with coordinated timing across the PROBAREX system.
Route instruments between DUTs and test points. General-purpose relay routing and guarded low-leakage paths are directions to explore. Topology, ratings and leakage targets remain open.
A guarded triaxial input and low-current measurement add-on for the standalone unit. Ratings and leakage targets remain open.
The SMU is engineering development hardware. The next phase is to establish real performance through bring-up, calibration and characterization.
An independent electronics development project under the PROBAREX brand.
Commercial and technical inquiries: info@burkartstudios.com · (505) 933-5461
Local interface concept defined for the 3.5-inch touchscreen and front status display: source and measure readouts, live trend plot, and output control. Firmware and remote command set in development.
The schematic and functional reference describe the card architecture, circuit design and intended operation. Both documents are engineering references; specifications remain design targets until verified on assembled hardware.
Access protected downloads ↗Shared password required for schematic Rev A.3 and Functional Reference A.4.