Technical downloads ↗
PROBAREX / modular precision instrumentation

One instrument.
A bigger idea.

Meet the PRX-SMU-001. A compact, isolated source-measure instrument built for standalone operation and the PROBAREX modular platform.

Explore the SMU ↗Discover the platform
PRX-SMU-001 · ENGINEERING DEVELOPMENT
PRX-SMU-001 SMU with PROBAREX panel graphics, top touchscreen, front OLED and five measurement terminals
±40 VFull-range voltage target
±200 mASource and sink current target
4 quadrantsBipolar source-measure architecture
One platformStandalone to coordinated chassis
The purpose

Precision should be
easier to scale.

PROBAREX began with a practical need for capable source-measure instrumentation at a more accessible cost per channel.

The PROBAREX platform connects instrument cards through shared chassis and backplane infrastructure. Each card retains its own instrument function; the SMU also operates in a standalone enclosure. A future PROBAREX chassis adds shared infrastructure as your system grows.

Put it near the DUT.

A compact isolated instrument can sit beside a device, fixture or sensor setup, reducing long force and sense cable runs.

Grow card by card.

The platform is intended to carry one instrument into a coordinated multi-card system with common timing and control.

Service the instrument.

Replaceable instrument cards make repair and expansion part of the architecture from the beginning.

SMU / PRX-SMU-001

Source. Sink. Measure.

Apply a voltage and measure current, or control current and measure voltage. Explore device behavior with two-wire or remote Kelvin sensing and a dedicated guarded low-current path.

SINKSOURCESOURCESINK+V+I−V−I

Conceptual operating quadrants. Available output depends on voltage, current, compliance and thermal limits.

Preliminary design targets. Terminal accuracy, noise, settling, low-current floor and thermal derating require assembled-hardware validation.
PRELIMINARY CAPABILITY OVERVIEW
Output voltage±40 V full range / ±4 V low range
Source / sink currentUp to approximately ±200 mA
Power envelopeUp to approximately 8 W at DUT terminals
Current measurementNominal ±200 mA, ±20 mA and guarded ±20 µA ranges
SensingTwo-wire local / four-wire remote Kelvin
ComplianceIndependent positive and negative current limits
ControlAnalog CV/CC loops with digital supervision
InterfacesStandalone USB and RS-485; PROBAREX card-edge interface
ProtectionHardware fault latch, output inhibit and relay disconnect
Precision and low-current design

A 20-bit voltage-command DAC provides ideal steps of approximately 76.3 µV on the ±40 V range and 7.63 µV on the ±4 V range. ADS1263 conversion and external precision references support measurement and calibration. Actual accuracy and useful resolution depend on the complete analog system.

Tens-of-nanoamps measurement is a design objective. Useful measurement into the hundreds-of-picoamps region remains a characterization goal, subject to leakage, guarding, cleanliness, noise and settling.

Example applications

Device I–V characterization, diode and transistor evaluation, sensor excitation and readout, leakage-current investigations, and automated source-measure sequences. Application performance will be established during validation.

The single-channel instrument

Small on the bench.
Clear at a glance.

A compact 116 × 176 × 71 mm enclosure with an integrated touchscreen for local control and USB and RS-485 for remote operation.

PRX-SMU-001 front panel showing OLED status display and labeled Guard, Sense and Force terminals
CAD RENDER · PRX-SMU-001 FRONT PANEL
PRX-SMU-001

Full local control.

A top-mounted 3.5-inch capacitive touchscreen brings settings, measurements and plots to the instrument. The front OLED keeps essential readings visible from the bench.

  • Front status displayProposed 1.54-inch BuyDisplay ER-OLED1.54-1W, mounted vertically. Voltage, current and output state remain visible when stacked.
  • Top touchscreenIntegrated 3.5-inch capacitive touchscreen using the BuyDisplay ER-TFT035IPS-6-4405.
  • Five measurement terminalsGuard, Sense +/− and Force +/− with shrouded banana connections.
  • Physical power controlRear-panel momentary power button keeps the front measurement area clear.

The PRX-SMU-001 supports local touchscreen control, remote operation and stacking. Stacking covers the top touchscreen; the front OLED keeps essential readings visible.

Rear-panel connections

Connect. Control. Power.

The rear panel brings USB, RS-485 and 24 V DC power together, alongside the power button and guarded input connector.

A clear view of the connections behind the standalone instrument.

PRX-SMU-001 rear panel showing guarded input connector, power button, RS-485, USB and 24 V DC input
Rear panel concept, shown with the optional guarded triax input and the DC jack in its planned next-revision position. Connector pin order, polarity marking and ratings are provisional.
Size and construction

A compact instrument,
in perspective.

The single-channel enclosure measures 116 mm wide, 176 mm deep and 71 mm high—approximately 4.57 × 6.93 × 2.80 inches. The three views below share a common scale.

SMU enclosure overall dimensionsTop, front and side envelope views at a common scale. Width 116 mm or 4.57 inches, depth 176 mm or 6.93 inches, height 71 mm or 2.80 inches. Simplified outlines.TOPFRONTSIDE116 mm / 4.57 in176 mm / 6.93 in116 mm / 4.57 in71 mm / 2.80 in176 mm / 6.93 in71 mm / 2.80 inSMU / SINGLE-CHANNEL ENCLOSURENominal enclosure envelope · Simplified orthographic outlines · Views share a common scaleOverall size illustration. Connector projections and detailed panel machining are excluded.
Nominal Takachi EXP12-7-18 enclosure envelope. Simplified outlines illustrate overall size. Connector projections and panel-machining details are excluded.
PRX-SMU-001 / the instrument card

The engineering inside the SMU.

The main PCB has a nominal footprint of approximately 100 × 160 mm (3.94 × 6.30 inches). The card combines source-measure circuitry, isolated power conversion, analog control loops, conversion, protection and its own controller.

The reference rendering shows the main PCB and its front-terminal mezzanine before separation. In the assembled chassis, the mezzanine moves to the front panel.

SMU card and enclosure footprint comparisonA nominal 100 by 160 millimeter main PCB footprint inside a 116 by 176 millimeter enclosure footprint at the same scale.MAIN PCB≈100 × 160 mm3.94 × 6.30 inNominal board footprintEnclosure footprint 116 × 176 mm / 4.57 × 6.93 inFootprint comparison · Centered for illustration · Component and connector projections excluded
Footprint comparison at a common scale. Board placement is illustrative.
PRX-SMU-001 SMU populated PCB CAD rendering with source-measure circuitry, power conversion, PROBAREX card-edge interface and attached front-terminal mezzanine
PCB CAD rendering from Functional Reference A.4. Illustrative component placement may differ from the final build. Select the image to inspect it at full size.
Beyond a single instrument

The card is the instrument.
PROBAREX connects the system.

The SMU is the first card for PROBAREX, the modular backplane platform that connects instruments into one system. The planned chassis shares power, cooling, communications and synchronization while each instrument retains its own function.

The current platform direction explores up to sixteen cards in opposing front and rear slot banks. Mechanical design, thermal capacity and final channel count remain development items.

Timing and backplane architecture

The backplane provides private low-speed serial links, a common 10 MHz reference, differential system synchronization, a 7.3728 MHz ADC clock, card event signaling and a chassis output-inhibit path. Reserved high-speed lanes provide options for future cards. Their protocols and bandwidth are still to be defined.

Platform concept
SMU
POWER
SUPPLY
DYNAMIC
LOAD
PROBAREX BACKPLANE
24 V power · control · clocks · synchronization · inhibit
DIGITIZER
SWITCHING
MATRIX
The SMU is in hardware development. The chassis and additional instrument cards are planned concepts.
Instrument roadmap

Build the bench around the task.

After the SMU, the proposed development sequence expands into power delivery, controlled loading and waveform capture.

±
Current development

SMU

Precision source and measurement for device characterization and automated testing.

Next milestone
Bring-up, calibration and characterization
⎓
Planned next

Power supply

A two-channel programmable supply built around independently floating outputs, not a conventional common-ground bench design. Channels can be connected in series, configured as positive and negative rails, or run independently without creating unwanted ground paths.

Design targets
  • Output power: 20 W per channel, 40 W total
  • Isolation: fully galvanically isolated, floating outputs
  • Regulation: constant voltage / constant current (CV/CC)
  • Programming: digitally programmable voltage and current limit
  • Readback: precision voltage and current monitoring
  • Remote sensing: optional Kelvin sense
  • Output control: independent hardware disconnect per channel, with synchronized enable
  • Input power: external DC supply through an auxiliary power connection
Voltage, current and noise targets to be defined.
↘
Planned after supply

Dynamic load

Programmable steady and changing loads for power supplies, batteries and converters.

Targets to define
Sink power · operating modes · transient response
∿
Planned after load

Digitizer

Waveform acquisition with coordinated timing across the PROBAREX system.

Concept targets: 2 channels · 50 MHz bandwidth · 125 MS/s · 14-bit
Expansion candidate

Switching matrix

Route instruments between DUTs and test points. General-purpose relay routing and guarded low-leakage paths are directions to explore. Topology, ratings and leakage targets remain open.

Expansion candidate

Picoammeter input

A guarded triaxial input and low-current measurement add-on for the standalone unit. Ratings and leakage targets remain open.

Development

Designed carefully.
Proven through measurement.

The SMU is engineering development hardware. The next phase is to establish real performance through bring-up, calibration and characterization.

Built by James Burkart

An independent electronics development project under the PROBAREX brand.

Commercial and technical inquiries: info@burkartstudios.com · (505) 933-5461

  1. Hardware architecture and schematicREFERENCE AVAILABLE
  2. Single-channel enclosure and displaysCONCEPT DEVELOPMENT
  3. Board bring-up and protection checksBOARDS FABRICATED · BRING-UP PENDING
  4. Calibration and electrical characterizationAWAITING BRING-UP
  5. Control software and local GUI

    Local interface concept defined for the 3.5-inch touchscreen and front status display: source and measure readouts, live trend plot, and output control. Firmware and remote command set in development.

    CONCEPT DEVELOPMENT
  6. Multi-card chassis and future instrumentsPLANNING

CONTENT BASIS
PRX-SMU-001 · Hardware Rev A
Functional Reference A.4 · 5 September 2026
Chassis concepts updated November 2026

Engineering documentation

Go deeper into the SMU.

The schematic and functional reference describe the card architecture, circuit design and intended operation. Both documents are engineering references; specifications remain design targets until verified on assembled hardware.

Access protected downloads ↗